The author assumes no responsibility or liability for any errors or omissions in the content of this site. The information contained in this site is provided on an "as is" basis with no guarantees of completeness, accuracy, usefulness or timeliness.
HOW TO USE:
Thermodynamic Properties of Saturated Steam (Steam Tables)
Temperature Range: 0.01 - 373.95 ℃
Pressure Range: 0.001 - 22.064 MPa
STEP BY STEP
1. Dial in the value of either the Temperature (in ℃) or the Pressure (in MPa) with the calculator
2. Press the "T" calculator button if Temperature, or "P" if Pressure
3. Press the "=" calculator button to get all interpolated thermodynamic properties at defined T or P
e.g. for saturated steam at 98.5 Celsius, dial in the following buttons: 9 --> 8 --> . --> 5 --> T --> =